4 mm Pelletized Activated Carbon for Odor Control at Photovoltaic Power Plants

Blog
Oct 21, 2026
Introduction

A customer recently asked us about odor control at a photovoltaic power plant. They had tried 0.8 mm pelletized activated carbon, but air could barely pass through the filter. Now, they are looking for 4 mm pelletized activated carbon with an iodine value of 1000 mg/g.

This raises a practical question: will larger pellets solve the airflow problem while still removing the unwanted odors?

The answer depends on more than pellet size or iodine value. The filter design, operating conditions, and compounds causing the odor all affect the result. Before choosing a carbon grade, it is worth checking these factors to avoid buying a product that looks good on paper but does not work well in the actual system.

Table of Contents

A customer recently asked us about odor control at a photovoltaic power plant. They had tried 0.8 mm pelletized activated carbon, but the pellets were so small and tightly packed that air could barely pass through the filter. They are now looking for 4 mm pelletized activated carbon with an iodine value of 1000 mg/g.
At first, this may sound like a simple product choice. A higher iodine value can be a useful sign of adsorption capacity, and larger pellets may help air pass through the filter more easily. But neither number alone can guarantee good odor removal.
For an industrial filter, activated carbon needs to do two things: capture the compounds causing the odor and let enough air pass through the carbon bed.

Quick Answer

For odor adsorption at a photovoltaic power plant, 4 mm pelletized activated carbon with an iodine value of 1000 mg/g may be worth testing if the existing 0.8 mm carbon creates too much resistance to airflow.
Under similar filter conditions, larger pellets may help lower the pressure drop. Actual results still depend on the filter design, carbon-bed depth, airflow rate, carbon properties, humidity, and the compounds causing the odor.
An iodine value of 1000 mg/g is a useful product specification, but it does not tell you exactly how well the carbon will remove every odor compound. Before placing a bulk order, confirm the odor source, operating conditions, required airflow, and target gas components.

Odor control and air filtration at a photovoltaic power plant

1. Why Can 0.8 mm Activated Carbon Restrict Airflow?

The customer’s experience points to a common issue in gas filtration: activated carbon may have good adsorption properties but still be a poor fit for a filter if the carbon bed makes it too hard for air to pass through.
Pellet diameter is one factor that affects airflow. When air moves through a packed carbon bed, it has to pass through the gaps between the pellets. Under otherwise similar conditions, smaller pellets usually leave narrower gaps and create a higher pressure drop.
This does not mean smaller pellets are always the wrong choice. They can work well in some systems when the filter is designed for them. But if the equipment cannot maintain the required airflow, the carbon size and the filter setup both need to be checked.

Why consider 4 mm pellets?

Compared with 0.8 mm pellets, 4 mm pellets are much larger. In a well-designed carbon bed, they can leave more open space for air to pass through and may reduce pressure drop.
Possible benefits for this application include:

  • Lower airflow resistance: Larger pellets may help the filter handle the required air volume with less pressure loss.
  • A better fit for some industrial filters: This pellet size may suit certain packed-bed filters or canister designs.
  • Less risk from fine-particle blockage: A product with controlled fines may help keep airflow more stable.

These are possible benefits, not guaranteed results. Pressure drop also depends on bed depth, how tightly the carbon is packed, vessel diameter, air speed, pellet shape, fines content, and any moisture or dust that builds up in the bed. Check the 4 mm product in the actual filter setup, not by diameter alone.

Check the filter before replacing the carbon

If airflow is already poor, changing the carbon is only one part of the check. See whether the previous bed was overfilled or packed too tightly, whether the pellets contained too many fines, whether moisture caused clumping, and whether the inlet screen or downstream filter is blocked. The fan’s available pressure and the filter’s required airflow also matter.
If the filter itself is too small for the job, switching from 0.8 mm to 4 mm carbon may not solve the problem completely.

4 mm pelletized activated carbon for industrial gas purification

2. Is an Iodine Value of 1000 mg/g Enough for Odor Removal?

An iodine value of 1000 mg/g is useful when comparing activated carbon products. It commonly indicates adsorption capacity for small molecules and the carbon’s micropores.

However, iodine value is not a universal score for odor removal.
Industrial odors can come from many different compounds, and each compound behaves differently inside activated carbon. Adsorption can depend on molecule size, polarity, concentration, humidity, temperature, pore-size distribution, and the carbon’s surface properties.

That is why two activated carbon products with similar iodine values may perform differently against the same odor.

For the proposed 4 mm pelletized activated carbon, an iodine value of 1000 mg/g is an important starting point. The next question is whether its pore structure and surface properties match the actual contaminants. Ask the supplier for the available technical data sheet and check the following details:

Parameter Why it matters
Iodine value Useful for comparing adsorption-related properties, but it does not prove performance against every odor compound.
Pellet diameter Affects the open spaces between pellets and may affect pressure drop.
Hardness and abrasion resistance Help show how well pellets may hold up during transport, loading, and use.
Fines content Too many small particles may increase airflow resistance or cause blockage.
Moisture content High moisture may affect adsorption capacity and how the carbon works.
Bulk density Helps estimate how much carbon is needed to fill a filter vessel.
Pressure-drop data Can help assess whether the carbon suits the planned airflow and bed size, if test data are available.
Impregnation or surface treatment May be needed for certain compounds that untreated activated carbon does not capture well.

Not every supplier provides every figure in the same format. Where possible, compare products using the same test methods and conditions.

3. What Is Causing the Odor at the Photovoltaic Power Plant?

Before choosing an activated carbon grade, find out where the odor comes from.

A photovoltaic power plant does not always produce one specific type of exhaust gas. Odors may come from support processes, maintenance work, wastewater systems, or sources near the site. The right treatment depends on what is actually released and how it enters the airflow.

Possible sources to check include:

  • Wastewater and drainage systems: Some wastewater, sumps, or drains can produce unpleasant odors. The compounds involved depend on the water and operating conditions.
  • Waste storage or handling areas: Stored organic waste or contaminated materials may release odor-causing compounds.
  • Support equipment and maintenance work: Cleaning products, lubricants, solvents, or other chemicals may be relevant if they are used or released near the air intake.
  • Sources outside the site: Odors noticed inside the plant boundary may come from nearby industrial activity, farms, or other neighboring sources.

These are possible areas to investigate, not assumptions about every photovoltaic power plant. The actual source needs to be checked.

This matters because different compounds may need different types of activated carbon. If the odor comes from compounds that standard activated carbon can capture well, a suitable standard grade may be enough. If untreated carbon does not work well against the target compounds, a specially selected or impregnated grade may be worth testing.

For example, some sulfur-containing gases, acidic gases, and basic gases may need a particular surface treatment or impregnation to reach the required removal level. The right choice depends on the exact compound, its concentration, humidity, and operating conditions. Do not choose a treatment just because someone describes the odor as strong or chemical.

If the odor source is not clear, record where it is strongest, when it appears, and whether it changes when equipment runs or maintenance takes place. If possible, collect an air sample or arrange gas testing. This can help avoid buying a high-specification carbon that does not match the actual pollutant.

Airflow comparison between 0.8 mm and 4 mm pelletized activated carbon in filter beds

4. How to Check 4 mm Pelletized Activated Carbon for This Application

For a filter that had trouble with 0.8 mm carbon, the evaluation should cover both airflow and adsorption.

Step 1: Confirm the required airflow

Record the normal and maximum airflow through the filter. If the system has a minimum ventilation requirement, use it as a target instead of judging performance only by how much air you can feel at the outlet. Also check the fan’s available pressure and the maximum pressure drop the carbon bed can handle.

Step 2: Check the filter size

The vessel diameter, bed depth, inlet and outlet layout, and amount of carbon all affect performance. A deeper bed gives the gas more time to contact the carbon, but it also adds airflow resistance.
The goal is not simply to use the largest pellets possible. It is to choose a pellet size and bed design that allow enough air to pass through while giving the carbon enough contact with the contaminants.

Step 3: Check the carbon’s physical quality

Ask the supplier to confirm the nominal pellet diameter and share available information on fines, hardness, moisture, and bulk density.
Because airflow is already a problem in this case, fines content and pressure-drop performance are especially important. Do not focus only on the 4 mm size listed on the product sheet.

Step 4: Match the carbon to the odor

If the compound causing the odor is known, discuss its concentration, relative humidity, temperature, and expected load with the supplier.
If the compound is unknown, do not make the choice based on iodine value alone. Testing a representative sample or running a properly planned trial can help show whether the carbon is suitable.

Step 5: Test under real working conditions

Before buying a large quantity, test the carbon under conditions as close as possible to those in the actual system.
Useful checks include:

  • Airflow before and after the carbon is loaded
  • Pressure drop across the carbon bed
  • Inlet and outlet levels of the target compound, if they can be measured
  • How odor-control performance changes over time, not just right after startup
  • Performance at the site’s normal temperature and humidity

A simple smell check may show an obvious change, but it cannot reliably measure removal efficiency or prove that a specific pollutant has been controlled. Instrument readings are better when the target compound can be tested.

Industrial activated carbon filter for gas treatment

5. Common Problems to Watch for During Operation

Even with a suitable carbon grade, operating or maintenance issues can lead to poor filter performance.

Problem 1: Airflow is still low after switching to 4 mm pellets

Do not assume the carbon itself is the problem. Check bed depth, packing, fines, moisture, the inlet screen, the downstream filter, and fan pressure. Compare the measured airflow and pressure drop with the system’s design limits.
If pressure drop is still too high, the filter layout or operating conditions may need to change. Simply switching carbon grades may not be enough.

Problem 2: Airflow is fine, but the odor remains

There are several possible reasons: the carbon may not match the target compound, the gas may not spend enough time in contact with the carbon, or the carbon may be close to used up. Another possibility is that the odor source was not correctly identified in the first place.
Before changing to another grade or an impregnated product, confirm what is actually in the air. Otherwise, a new carbon may lead to the same problem.

Problem 3: Odor control is good at first but fades quickly

Activated carbon can only hold a limited amount of contaminants. Its service life depends on contaminant levels, airflow, temperature, humidity, the amount of carbon in the bed, and other substances in the air that may compete for adsorption.
Even carbon with a high iodine value may be used up quickly if the contaminant load is high or the carbon’s pore structure is not a good match for the target compound.
Track operating results and set a replacement point based on the target compound or a suitable operating measure. Avoid relying on a fixed replacement schedule when there is no data to support it.

Problem 4: Performance changes during humid weather

Water vapor can compete with some contaminants for adsorption sites or affect how certain compounds behave. The effect depends on the carbon and the target compound. High humidity can reduce performance in some applications, but the size of the effect varies.
If humidity changes a lot at the site, include those conditions when testing the carbon. Do not make the decision based only on results from a dry laboratory.

6. What Information Should You Send Before Asking for a Quote?

A supplier can give more useful advice if you share the operating conditions, not just the pellet size and iodine value. For this application, the following information will help narrow down the options:

Information What to provide
Application Odor adsorption at a photovoltaic power plant
Existing carbon 0.8 mm pellets, if confirmed
Current problem Airflow restriction through the previous carbon bed
Requested specification 4 mm pelletized activated carbon, iodine value 1000 mg/g
Odor source Known source or suspected process area
Target compounds Gas test results, if available
Airflow Normal and maximum flow rate
Filter design Vessel dimensions, bed depth, and filter type
Operating conditions Temperature, relative humidity, and expected contaminant level
Required quantity Sample amount or estimated bulk quantity

If you do not have all this information, start with what you know. The odor source, airflow, and filter dimensions are especially useful for deciding what to check next.

Frequently Asked Questions

Is 4 mm activated carbon better for odor removal than 0.8 mm carbon?

Not in every case. But if 0.8 mm pellets create too much pressure drop in a packed carbon bed and reduce the airflow, 4 mm pellets may be a better option. The final choice depends on the filter design, airflow needs, contact time, and target compounds.

Does an iodine value of 1000 mg/g guarantee good odor removal?

No. Iodine value is a useful indicator, but it cannot predict how well the carbon will remove every odor compound. The target gas, pore structure, surface properties, humidity, and contact time also matter.

Can standard pelletized activated carbon remove every odor at a photovoltaic power plant?

No. One carbon grade will not work equally well for every odor source. Standard activated carbon may work for some compounds, while others may need a specially selected or impregnated grade. Identify the target compounds before choosing the treatment.

How can I lower pressure drop in an activated carbon filter?

Check pellet size, fines content, bed depth, how tightly the carbon is packed, vessel size, and fan capacity. Larger pellets may help, but blockage, moisture, or an undersized filter can also cause high pressure drop. Find the cause before making a change.

Should I test the carbon before buying in bulk?

If the odor source or operating conditions are unclear, testing a sample or running a pilot trial is a good idea. It lets you check both airflow and adsorption before placing a large order.

Choose the Carbon Based on the Actual Problem

For the photovoltaic power plant application discussed here, 4 mm pelletized activated carbon with an iodine value of 1000 mg/g is a reasonable option to evaluate, especially because the previous 0.8 mm product caused airflow problems.

But these two specifications should not be the only basis for the decision.
First, confirm the required airflow, filter size, carbon’s physical properties, and the compounds causing the odor. Then test the carbon under conditions close to the real application. This is more reliable than choosing by iodine value alone and helps avoid paying for a high-specification product that does not solve the problem.

If you are looking at pelletized activated carbon for industrial odor control or gas purification, share the application, required airflow, filter dimensions, and any available gas test results. This information can help narrow the choices and show whether standard or specially treated activated carbon is a better fit.

Related News

Contact XingSen
For any enquiries or quotations pertaining to Xinsen services, simply contact us or request a quote directly.
Phone: +86 15737108714
Email: [email protected]
WhatsApp: +86 15737108714
Free samples
Request A Free Quote
Our experts will give you a reply within 2 hours and help you select the right activated carbon you want.